Table of contents
- What is the difference between modular, semi-modular and non-modular cabling?
- Comparison table: modular vs. semi-modular vs. non-modular
- How does the type of cabling affect airflow and temperature?
- Technical criteria that matter before choosing your cabling
- What mistakes are commonly made when buying a PSU?
- What wattage and model do you need for your usage profile?
- FAQs about cabling and power supplies
- Final verdict
What is the difference between modular, semi-modular and non-modular cabling?
In a non-modular PSU (also known as fixed-cable), all power cables are hardwired directly from the internal PCB through a single plastic grommet. This includes the 24-pin ATX cable, the 8-pin (or 4+4-pin) CPU EPS cable, the 6+2-pin PCIe leads, and several SATA and Molex strands. If your system only uses a SATA SSD and a graphics card, the surplus cables must be folded and tucked away behind the PSU shroud, taking up between 200 cm³ and 400 cm³ of usable volume.
In a semi-modular PSU, the cables essential for the PC to boot (the 24-pin ATX connector and the 8-pin CPU EPS connector) are hardwired at the factory, while the cables for graphics cards (6+2-pin PCIe) and storage peripherals (SATA and Molex) attach to dedicated sockets on the rear panel. This reduces the main bundle to just 2 permanent cables, eliminating 3 to 5 unnecessary branches in straightforward builds.
In a 100% modular PSU, no cable is attached to the chassis: every connector, including the main 24-pin one, plugs in individually according to the needs of the build. This layout adds a secondary internal board with female connectors, which typically increases the length of the metal chassis by around 10 mm or 20 mm in conventional ATX power supplies.
Modular, semi-modular or non-modular? A direct technical comparison
The following table summarises the operational and construction differences between the three formats available on the market:
| Criterion | Non-Modular PSU | Semi-Modular PSU | Modular PSU |
|---|---|---|---|
| Detachable cables | 0% (all hardwired) | Partial (PCIe, SATA and Molex only) | 100% (all detachable) |
| Average build time | 45 to 60 minutes | 25 to 35 minutes | 20 to 30 minutes |
| Space required in the case | Requires a bottom compartment of >180 mm | Standard (>150 mm) | Standard or compact (<140 mm) |
| Added electrical resistance | 0 mΩ (direct connection) | Minimal (PCIe/SATA only) | Low (additional connectors on the PCB) |
| Use of flat cables | Available on advanced models | Common | Standard in this category |
| Impact on base price | Cheapest option | +15% to +25% over non-modular | +30% to +50% over non-modular |
| Ease of cleaning | Moderate (cables get in the way when dismantling) | High | Very high (the chassis can be removed on its own) |
How does the type of cabling affect airflow and temperature?
The belief that surplus cables dramatically raise component temperatures is a myth in modern mid-tower chassis: thermal tests show variations of just 0.5 °C to 1.5 °C on the CPU and GPU when cables are routed behind the metal tray. However, in compact MicroATX or Mini-ITX chassis with volumes below 25 litres, a bundle of surplus cables 150 mm thick can directly obstruct the 120 mm or 140 mm front fan, cutting the fresh airflow from 50 CFM to under 30 CFM.
Cable format matters just as much as modularity: flat cables make routing through rear channels less than 15 mm deep easier, allowing the side panel to close without pressing against it. What is more, using extra-long cables on PSUs such as Tacens units avoids adding intermediate extensions, which introduce voltage drops of up to 0.05 V per line on 12V rails under heavy loads of 30 A or 40 A.
Technical criteria that matter before choosing your cabling
Before deciding whether you need detachable cables, assess these mechanical and electrical factors that determine service life and power stability:
- Fan diameter and noise level: Compact PSUs usually integrate 120 mm fans spinning at 1500 RPM or more to dissipate heat, generating noise of 20 dB to 28 dB. A 140 mm fan moves the same airflow at lower speeds, keeping the sound level at 12 dB under average loads of 50%.
- Capacitor quality: Japanese-made primary capacitors rated for 105 °C withstand twice as many thermal cycles and up to 4 times the service life of generic models limited to 85 °C under sustained load spikes.
- Real energy efficiency at 230V EU: In Europe, the 80 PLUS standard requires specific efficiency levels depending on the tier. An 80 PLUS Gold PSU must deliver a minimum efficiency of 90% at 20% load, 92% at 50% load and 89% at 100% load. For example, to supply 350 W to the system at 90% efficiency, the draw at the wall works out at: "350 W / 0.90 = 388.8 W". Over a year of intensive use (1460 h), the accumulated consumption is: "388.8 W × 1460 h = 567.6 kWh".
- Connectors and current standards: The classic 8-pin PCIe connector supplies up to 150 W, and the 8-pin CPU EPS connector delivers up to 235 W. On recent graphics cards, the new 12V-2x6 standard (a revision of PCIe CEM 5.1 and ATX 3.1 with shortened sense pins) delivers up to 600 W through a single connector, reducing the risk of poor contact compared with the original 16-pin 12VHPWR connector.
- Legal compliance versus voluntary certifications: CE marking and the RoHS directive are mandatory legal requirements for selling products in the European Union and do not certify superior quality. Certifications such as TUV Rheinland or the CLEAResult 80 PLUS seal do represent independent testing for safety and energy performance.
What mistakes are commonly made when buying a PSU?
- Spending more on modularity than on internal quality: Paying a 40% premium for a modular PSU with 85 °C components instead of buying a non-modular or semi-modular unit with Japanese 105 °C capacitors and Gold certification.
- Mixing cables from different modular PSUs: The connections that plug into the PSU are not standardised between manufacturers or even between series from the same brand; swapping modular cables can send a 12V line to a 0V ground pin, destroying motherboards or drives within milliseconds.
- Oversizing the wattage without justification: A mid-range system with a 65 W processor and a 200 W graphics card draws less than 320 W while gaming. Fitting a 1000 W unit puts typical usage at 15% or 25% load, where the efficiency curve drops below 85%.
What wattage and model do you need for your usage profile?
Below are the recommended models from Tacens' Radix range with Gold certification for each type of configuration:
Entry-level profile / Advanced office use (draw of 150 W to 300 W)
For computers intended for office work, light editing or basic gaming with cards that have no dedicated power connectors or just a single 8-pin PCIe:
- Recommended model: 1RECOX550 (550 W, weight of 1350 g, dimensions of 150x160x85 mm).
- Technical justification: It features extra-long flat cables that make routing easy in standard cases, a quiet 140 mm fan and enough connectors for everyday use (1x ATX 24 PIN, 1x EPS 4+4 PIN, 1x PCIe 6+2 PIN, 3x SATA and 2x Molex).
Mid-range gaming profile (draw of 300 W to 450 W)
For systems with graphics cards of up to 220 W TDP and 6 to 8-core processors:
- Recommended model: 1RECOX650 (650 W, weight of 1400 g, dimensions of 150x160x85 mm).
- Technical justification: Its 650 W keep the PSU close to the optimal efficiency point of 50% load. It includes a 140 mm fan, flat cables and an expanded connector set (4x SATA and 2x Molex).
High-performance gaming profile (draw of 450 W to 600 W)
For configurations with demanding graphics cards of up to 300 W that require dual 8-pin PCIe connectors:
- Recommended model: 1RECOX750 (750 W, weight of 1479 g, dimensions of 150x160x85 mm).
- Technical justification: It offers 2x PCIe 6+2 PIN, 6x SATA sockets for multi-drive configurations and extra-long flat cables that avoid the need for extensions in full-size chassis.
Workstation and enthusiast profile (draw of over 600 W)
For builds with high-end processors and power-hungry graphics cards:
- Recommended model: 1RECOX850 (850 W, weight of 1548 g, dimensions of 150x160x85 mm).
- Technical justification: It integrates Japanese Toshin Kyogo capacitors rated at 105 °C to maximise thermal durability, cooling via a 140 mm fan with a noise level of just 12 dB, and a layout with 2x PCIe 6+2 PIN and 6x SATA sockets.
Products mentioned

RADIX ECO X 550
| Weight | 1350g |
|---|---|
| Dimensions | 150x160x85mm |
| Certifications | ATX12V CE ROHS TUV |
| Connectors | /1x ATX MB 24 PIN /1x EPS +12V 4+4 PIN /1x PCIe 6+2 PIN /3x SATA /2x Molex 4 PIN |
| Extras | Black, extra-long flat cables |
| Colour | Black |

RADIX ECO X 650
| Weight | 1400g |
|---|---|
| Dimensions | 150x160x85mm |
| Certifications | ATX12V CE ROHS TUV |
| Connectors | /1x ATX MB 24 PIN /1x EPS +12V 4+4 PIN /1x PCIe 6+2 PIN /4x SATA /2x Molex 4 PIN |
| Extras | Black, extra-long flat cables |
| Colour | Black |

RADIX ECO X 750
| Weight | 1479g |
|---|---|
| Dimensions | 150x160x85mm |
| Certifications | ATX12V CE ROHS TUV |
| Connectors | /1x ATX MB 24 PIN /1x EPS +12V 4+4 PIN /2x PCIe 6+2 PIN /6x SATA /3x Molex 4 PIN |
| Extras | Black, extra-long flat cables |
| Colour | Black |

RADIX ECO X 850
| Weight | 1548g |
|---|---|
| Dimensions | 150x160x85mm |
| Certifications | ATX12V CE ROHS TUV |
| Connectors | /1x ATX MB 24 PIN /1x EPS +12V 4+4 PIN /2x PCIe 6+2 PIN /6x SATA /3x Molex 4 PIN |
| Extras | 105°C Japanese Toshin Kyogo capacitors |
| Colour | Black |
FAQs about modular and non-modular power supplies
Does a modular PSU offer more wattage or better electrical performance than a non-modular one?
No, the cabling format does not alter the rated wattage or voltage stability. A non-modular PSU with high-quality components delivers cleaner voltages with lower ripple than a low-end modular unit.
Can you buy spare modular cables if you lose them?
Only if they are made specifically for the exact model of your PSU, as the pinout scheme on the chassis panel varies between manufacturers. Using a cable from another model can bridge 12V lines to 5V or ground ports and burn out components.
Do flat cables affect cooling compared with round sleeved cables?
Flat cables take up less vertical profile and can be layered behind the chassis at a thickness of under 5 mm. This aids airflow by avoiding bulges at the pass-through openings towards the main components.
The best: A non-modular or semi-modular PSU with flat cables offers the same electrical stability as a modular one at a lower cost, freeing up budget for better 105 °C capacitors and 140 mm fans.
The worst: In very small Mini-ITX cases without a PSU shroud, hiding the surplus fixed cables is tricky and reduces the space available for ventilation.
Buy it if: You have an ATX or MicroATX chassis with a dedicated lower compartment for hiding cables and you want the greatest efficiency and durability for every pound spent.
Don't buy it if: You are building in an ultra-compact chassis of under 15 litres where every cubic centimetre counts; in that case, go for a 100% modular PSU in SFX format.